Home

Company Profile

Contact Us

Biotechnology
&
Biochemistry 

Chemistry

Zoology

Geology

Plant Sciences

Molecular Biology

Environmental Sciences

Spares, Accessories and Consumables

pH Meters(Ion/pH/mV/C

Multi-point (1...5) calibration of pH electrodes
Separate HELP key guides you at any moment in the language of your choice
Stores up to 7200 values (8 bit mode) or up to 3600 values (16 bit mode) time & date
Permits to recall graphic and digital data at the same time, ideal for titration purposes
Built-in analogue recorder shows measurements on the graphic display
Multi-point (2...19) calibration of ion-selective electrodes
Stores up to 5 calibration curves in memory
Incremental methods and direct concentration mode
Shows concentration in any user-defined unit
AC-line & rechargeable battery operation with programmable automatic shut-off
Optional 12 V car adaptor
Powerful set-up option permits to customise the meter to the needs of the user.
Selectable resolution down to 0.1 pH/ 1mV.

Automatic standardisation with any of nine pre-programmed and five user specified pH buffers.

Manual or automatic temperature compensation.

Temperature corrected pH mode permits to reference readings to a standard temperature.

Features mV calibration for accurate redox measurements.

GLP-compatible calibration of temperature probe.

Graphic display for better readability.

Stability indicator prompts the user when readings should be taken.

Hold function allows to freeze the display for convenient reading or recording.
No special software required for data acquisition.
Printer output on command or at timed intervals.
Two-way communication with any computer.
Programmable recorder output.
Programmable identification number for use with a printer or computer.

Password protection prevents any unauthorised access to the instrument

Shows percentage of remaining battery capacity


Oxygen/Ion/pH/mV/Conductivity/C

Ideal for environmental control
Keeps the connected electrode polarised even when switched off
Electrochemical multimeter
Simultaneous measurement of all parameters in the same solution
Optional 12 V car adaptor
Powerful set-up option permits to customise the meter to the needs of the user.
Selectable resolution down to 0.1 ppm/ 1%.
Automatic calibration with pre-programmed saturated 2 concentration table.
Manual or automatic salinity compensation up to 4% NaCl.
Automatic temperature compensation.
Manual pressure compensation.
Calibrates temperature probe for quality measurements.
Simultaneous temperature display.
Stability indicator prompts the user when readings should be taken.
Hold function allows to freeze the display for convenier reading or recording.
Scanning display mode enables an automatic sequential vies of all channels and offers the possibility to send the  measurtments simultaneously to a printer or computer.
Real-time clock displays time & date.
Stores up to 500 values including C, time & date.
No special software required for data-acquisition.
Simultaneous measurements in grounded solutions allowed.
Programmable recorder output.
Two-way communication with any computer using RS232.
Programmable identification number for use with a printer computer.
Password protection prevents any unauthorised access to the instrument.
pH/mV/ Ion mode: page10
Conductivity/ resistivity / Salinity mode: page 46.

Dissolved Oxygen Meters (Oxygen/Ion/pH/mV/Conductivity/C)


Separate HELP key guides you at any moment |t in the language of your choice
Keeps the connected electrode polarised even when switched off
Automatic pressure compensation and display 800-1100 hPa
Stores up to 7200 values (8 bit mode) or up to 3600 values (16 bit mode), + time & date
Built-in analogue recorder shows measurements on the graphic display
AC line & rechargeable battery operation with programmable automatic shut-off
Optional 12 V car adapter.
An oxygenmeter Its electrode function
Powerful set-up option permits to customise the meter to the needs of the user.
Selectable resolution down to 0.1 mg/l or 1%.Automatic calibration with pre-programmed saturated 2 concentration table.
Salinity compensation up to 40 %0 NaCl.
Automatic temperature compensation.
Automatic atmospheric pressure compensation.
GLP-compatible calibration of temperature probe.
Graphic display for better readability.
Hold function allows to freeze the display for convenient reading or recording.
No special software required for data acquisition.
Programmable interval from 1 up to 9999 seconds.
Printer output on command or at timed intervals.
Two-way communication with any computer using RS232.
Programmable recorder output.
Programmable identification number for use with a printer or computer.
Password protection prevents any unauthorised access to the instrument.
Shows percentage of remaining battery capacity.

An oxygenmeter Its electrode function according to the Clark principle with platinum as cathode and silver as anode in an electrolyte cell to which a polarisation voltage is applied. Oxygen gas present in the electrolyte is reduced to OH ions at the platinum cathode. The resulting current is diffusion limited and therefore proportional to the oxygen concentration in the sample solution. This current is amplified, corrected and displayed in mg/l or % of dissolved oxygen.


Ion Electrodes


with attached 6 Channel MCA Probe (MCA=Multi-Component Analysis)
Water Quality Monitoring System


Meter-less Ion-Selective Measurement